Quantcast
Channel: Symantec Connect - Backup and Recovery - 讨论
Viewing all articles
Browse latest Browse all 3749

SLP's ending with code 96

$
0
0
我需要解决方案

Hello everyone

Somebody can help me to check where is the reason about the status code. Last week we had to  insert on the library 100 cartridges to minimize this kind of errors, but today I see the same error. Could be I don't have the enough STU, but I need to know if is this the reason. Which is the log to check this?

May be I have to organize my SLP's, someby have any idea about how can I do it?

As can you see, this are the messages about it:

22-abr-2015 5:00:59 - requesting resource LCM_media_server01-hcart-robot-tld-0
22-abr-2015 5:00:59 - granted resource  LCM_media_server01-hcart-robot-tld-0
22-abr-2015 5:01:00 - begin Duplicate
22-abr-2015 5:01:00 - started process RUNCMD (pid=27132102)
22-abr-2015 5:01:01 - ended process 0 (pid=27132102)
22-abr-2015 5:01:01 - requesting resource media_server01-hcart-robot-tld-0
22-abr-2015 5:01:01 - requesting resource @aaaaj
22-abr-2015 5:01:01 - reserving resource @aaaaj
22-abr-2015 5:01:02 - end Duplicate; elapsed time 0:00:02
22-abr-2015 5:01:02 - Error nbjm (pid=25231436) NBU status: 96, EMM status: No media is available
22-abr-2015 5:01:02 - Error nbjm (pid=25231436) NBU status: 96, EMM status: No media is available
22-abr-2015 5:01:02 - Error nbjm (pid=25231436) NBU status: 96, EMM status: No media is available
unable to allocate new media for backup, storage unit has none available  (96)


Viewing all articles
Browse latest Browse all 3749

Trending Articles